Goniophotometer
Ivor, Martin ; Janáková, Ilona (oponent) ; Honec, Peter (vedoucí práce)
The thesis deals with the design of a goniophotometer and the GUI (Graphical User Interface), capable of evaluating the photometric parameters of light sources and luminaires. The introduction contains theoretical information about photometry, photometric parameters, light sources, lamps, as well as the theory of measuring these parameters, and basic globally used data formats, designed to store the parameters of light sources. The core of this thesis, then describes the hardware, that makes up the proposed device, and the software needed to control the measurement process, visualization and storing the results. The conclusion is an evaluation of the functionality of the described device, and the measurements that were mediated by it, and an overall summary of the results achieved.
Luminance scanning of luminaires and light sources
Ševčík, Ondřej ; Baxant, Petr (oponent) ; Škoda, Jan (vedoucí práce)
The work deals with the measurement of luminance curves of light sources using conventional and unconventional methods. The introductory part is devoted to the description of the visual system and basic photometric quantities. The main theoretical part is focused on the description of current methods of luminance curves measurement and new methods using the luminance analyzer. The uncertainty sources affecting the results are listed for each method at the same time. The thesis focuses on design of methodology of measuring luminance curves using brightness scans of light source and subsequent verification of the measurement procedure. Furthermore, a comparison of the results, obtained by the proposed procedure and the results of conventional goniophotometer with luxmeter measurements, was made.
Blízká fotometrie
Kutý, Tomáš ; Baxant, Petr (oponent) ; Škoda, Jan (vedoucí práce)
Tato diplomová práce je zaměřena na teoretické seznámení i praktické ověření dnes používaných postupů pro získání křivek svítivosti svítidel. Úvod práce seznamuje čtenáře s fotometrickými veličinami. Následně je teoreticky rozebrán postup pro sestrojení křivek svítivosti metodou vzdálené fotometrie a dále pak seznámení s fotometrií blízkého pole. Pro praktickou část bylo zvoleno několik svítidel, které byly měřeny luxmetrem nejprve z velmi blízké fotometrické vzdálenosti od svítidla a následně z velké vzdálenosti. Dalším krokem bylo získání fotografií svítidel v rovinách C 0 až 345° (s krokem 15°) pro úhel gama 0 až 180° (s krokem 5°). Naměřená data byly zpracovávány metodou zonálních toků a pomocí programů LumiDISP a Matlab. Dílčím výsledkem práce je ověření, zda je možné použít jasový analyzátor pro získávání křivek svítivosti, to znamená, zda křivky svítivosti získané jasovým analyzátorem budou odpovídat křivkám získaných luxmetrem. Dále práce zkoumá, zda je možné ze získaných fotografií svítidla z velmi blízké fotometrické vzdálenosti vytvořit křivky svítivosti pro libovolnou polohu a vzdálenost pozorovatele od svítidla.
Návrh konstrukce automatizovaného goniofotometru, polohovacího zařízení pro měření svítidel.
Minář, Petr ; Škoda, Jan (oponent) ; Blecha, Petr (vedoucí práce)
Tato bakalářská práce se zabývá konstrukčním řešením goniofotometru. První část je věnována přehledu obecných druhů konstrukcí goniofotometru, jejich vlastnostem a metodám, používaným při měření. V další části je proveden návrh celého zařízení včetně univerzálního upínacího mechanismu a pohonu pro automatizované řízení.
Vliv pozice svítidla uvnitř kulového integrátoru na výsledky měření
Vlček, Pavel ; Škoda, Jan (oponent) ; Motyčka, Martin (vedoucí práce)
Tato bakalářská práce se zabývá vlivem polohy svítidel s úzkou vyzařovací charakteristikou při měření v kulovém integrátoru. K proniknutí do dané problematiky jsou zde shrnuty základní světelně technické parametry. Zejména světelný tok, osvětlenost, prostorový úhel, svítivost a jas, následuje teplota chromatičnosti a index podání barev. Dále se práce zabývá měřícími přístroji. Nejprve základním prvkem, kterým je fotočlánek a poté na to navazujícími přístroji: luxmetr, jasoměr, spektroradiometr, goniofotometr a kulový integrátor. Práce také shrnuje základní informace o svítidlech. Po této teorii následuje laboratorní měření, které se zabývá měřením svítidel na goniofotometru, a v kulovém integrátoru. Měření na goniofotometru, je důležité z hlediska získání přesného světelného toku. Světelný tok z goniofotometru se porovná s jednotlivými naměřenými hodnotami v nastavovaných polohých při měření v kulovém integrátoru. Výsledkem je získat vliv polohy svítidla v kulovém integrátoru.
The Uncertainty Of Measurement In Lightlaboratory
Motyčka, Martin
This article has task to inform a reader of uncertainties of measurement in laboratory of light. In the first part there are mathematical descriptions of different types of uncertainties, including the methodology for their determination. The second part is focused in detailed description of standard uncertainties for measurement of the luminous flux, luminous intensity distribution and spectral power distribution. The last section provides practical calculations and results of standard uncertainties as an integral value or wavelength function.
Goniophotometer
Ivor, Martin ; Janáková, Ilona (oponent) ; Honec, Peter (vedoucí práce)
The thesis deals with the design of a goniophotometer and the GUI (Graphical User Interface), capable of evaluating the photometric parameters of light sources and luminaires. The introduction contains theoretical information about photometry, photometric parameters, light sources, lamps, as well as the theory of measuring these parameters, and basic globally used data formats, designed to store the parameters of light sources. The core of this thesis, then describes the hardware, that makes up the proposed device, and the software needed to control the measurement process, visualization and storing the results. The conclusion is an evaluation of the functionality of the described device, and the measurements that were mediated by it, and an overall summary of the results achieved.
Vliv pozice svítidla uvnitř kulového integrátoru na výsledky měření
Vlček, Pavel ; Škoda, Jan (oponent) ; Motyčka, Martin (vedoucí práce)
Tato bakalářská práce se zabývá vlivem polohy svítidel s úzkou vyzařovací charakteristikou při měření v kulovém integrátoru. K proniknutí do dané problematiky jsou zde shrnuty základní světelně technické parametry. Zejména světelný tok, osvětlenost, prostorový úhel, svítivost a jas, následuje teplota chromatičnosti a index podání barev. Dále se práce zabývá měřícími přístroji. Nejprve základním prvkem, kterým je fotočlánek a poté na to navazujícími přístroji: luxmetr, jasoměr, spektroradiometr, goniofotometr a kulový integrátor. Práce také shrnuje základní informace o svítidlech. Po této teorii následuje laboratorní měření, které se zabývá měřením svítidel na goniofotometru, a v kulovém integrátoru. Měření na goniofotometru, je důležité z hlediska získání přesného světelného toku. Světelný tok z goniofotometru se porovná s jednotlivými naměřenými hodnotami v nastavovaných polohých při měření v kulovém integrátoru. Výsledkem je získat vliv polohy svítidla v kulovém integrátoru.
Metody validace goniofotometru se zrcadlovým systémem a vliv výsledných křivek svítivosti na energetickou hospodárnost budov
Grinaj, Lukáš ; Dubnička, Roman ; Smola, Alfonz
LIDC is an important characteristic of luminaires used in the design of new lighting systems. Mirror system goniophotometers with are based on the principle of reflection of light emitted from luminaires on the mirrors. The accuracy of the LIDC measurement is influenced by many factors. This paper deals with measurement errors which occur with this type of goniophotometer, then methods of validation of goniophotometers using a mirror system is proposed. Based on these validation methods,accuracy of the LIDC measurement on goniophotometer with mirror system can be increased. This paper also deals with the impact of the choice of LIDC measured on goniophotometer with mirror system to the quality of interior lighting systems in the framework of the energy performance of buildings. The term energy performance of buildings means the amount of energy needed to meet all the energy needs associated with a standardized usage of the building.
Blízká fotometrie
Kutý, Tomáš ; Baxant, Petr (oponent) ; Škoda, Jan (vedoucí práce)
Tato diplomová práce je zaměřena na teoretické seznámení i praktické ověření dnes používaných postupů pro získání křivek svítivosti svítidel. Úvod práce seznamuje čtenáře s fotometrickými veličinami. Následně je teoreticky rozebrán postup pro sestrojení křivek svítivosti metodou vzdálené fotometrie a dále pak seznámení s fotometrií blízkého pole. Pro praktickou část bylo zvoleno několik svítidel, které byly měřeny luxmetrem nejprve z velmi blízké fotometrické vzdálenosti od svítidla a následně z velké vzdálenosti. Dalším krokem bylo získání fotografií svítidel v rovinách C 0 až 345° (s krokem 15°) pro úhel gama 0 až 180° (s krokem 5°). Naměřená data byly zpracovávány metodou zonálních toků a pomocí programů LumiDISP a Matlab. Dílčím výsledkem práce je ověření, zda je možné použít jasový analyzátor pro získávání křivek svítivosti, to znamená, zda křivky svítivosti získané jasovým analyzátorem budou odpovídat křivkám získaných luxmetrem. Dále práce zkoumá, zda je možné ze získaných fotografií svítidla z velmi blízké fotometrické vzdálenosti vytvořit křivky svítivosti pro libovolnou polohu a vzdálenost pozorovatele od svítidla.